CHECK FUNCTION
CONSULT
Ignition switch ON.
Select “INT LAMP” of “BCM”.
Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.
Check that the function operates normally according to the following conditions.
Monitor item | Condition | Status | |
---|---|---|---|
CDL LOCK SW | Door lock/unlock switch LH | LOCK | On |
UNLOCK | Off | ||
CDL UNLOCK SW | LOCK | Off | |
UNLOCK | On |
Is the inspection result normal?
YES>>Door lock/unlock switch LH is OK.
NO>>Refer to Diagnosis Procedure.
CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
Ignition switch OFF.
Disconnect door lock/unlock switch LH connector.
Check voltage between door lock/unlock switch LH harness connector and ground.
(+) | (–) |
Voltage (Approx.) | |
---|---|---|---|
Door lock/unlock switch LH | |||
Connector | Terminal | ||
D10 | 1 | Ground | Battery voltage |
2 |
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK DOOR LOCK/UNLOCK SWITCH CIRCUIT
Disconnect BCM connector.
Check continuity between BCM harness connector and door lock/unlock switch LH harness connector.
BCM | Door lock/unlock switch LH | Continuity | ||
---|---|---|---|---|
Connector | Terminal | Connector | Terminal | |
M18 | 11 | D10 | 2 | Yes |
14 | 1 |
Check continuity between BCM harness connector and ground.
BCM | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
M18 | 11 | Ground | No |
14 |
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK DOOR LOCK/UNLOCK SWITCH GROUND CIRCUIT
Check continuity between door lock/unlock switch LH harness connector and ground.
Door lock/unlock switch LH | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
D10 | 4 | Ground | Yes |
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK DOOR LOCK/UNLOCK SWITCH
Check door lock/unlock switch LH. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace door lock/unlock switch LH. Refer to Removal and Installation.
CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident.
YES>>
Inspection End.
CHECK DOOR LOCK/UNLOCK SWITCH
Ignition switch OFF.
Disconnect door lock/unlock switch LH connector.
Check continuity between door lock/unlock switch LH terminals.
Door lock/unlock switch LH | Condition | Continuity | ||
---|---|---|---|---|
Terminal | ||||
1 | 4 | Door lock/unlock switch LH | LOCK | No |
UNLOCK | Yes | |||
2 | LOCK | Yes | ||
UNLOCK | No |
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace door lock/unlock switch LH. Refer to Removal and Installation.
CHECK FUNCTION
CONSULT
Ignition switch ON.
Select “INT LAMP” of “BCM”.
Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.
Check that the function operates normally according to the following conditions.
Monitor item | Condition | Status | |
---|---|---|---|
CDL LOCK SW | Door lock/unlock switch RH | LOCK | On |
UNLOCK | Off | ||
CDL UNLOCK SW | LOCK | Off | |
UNLOCK | On |
Is the inspection result normal?
YES>>Door lock/unlock switch RH is OK.
NO>>Refer to Diagnosis Procedure.
CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
Ignition switch OFF.
Disconnect door lock/unlock switch RH connector.
Check voltage between door lock/unlock switch RH harness connector and ground.
(+) | (–) |
Voltage (Approx.) | |
---|---|---|---|
Door lock/unlock switch RH | |||
Connector | Terminal | ||
D103 | 1 | Ground | Battery voltage |
2 |
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK DOOR LOCK/UNLOCK SWITCH CIRCUIT
Disconnect BCM connector.
Check continuity between BCM harness connector and door lock/unlock switch RH harness connector.
BCM | Door lock/unlock switch RH | Continuity | ||
---|---|---|---|---|
Connector | Terminal | Connector | Terminal | |
M18 | 11 | D103 | 2 | Yes |
14 | 1 |
Check continuity between BCM harness connector and ground.
BCM | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
M18 | 11 | Ground | No |
14 |
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK DOOR LOCK/UNLOCK SWITCH GROUND CIRCUIT
Check continuity between door lock/unlock switch RH harness connector and ground.
Door lock/unlock switch RH | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
D103 | 4 | Ground | Yes |
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK DOOR LOCK/UNLOCK SWITCH
Check door lock/unlock switch RH. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace door lock/unlock switch RH. Refer to Removal and Installation.
CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident.
YES>>
Inspection End.
CHECK DOOR LOCK/UNLOCK SWITCH
Ignition switch OFF.
Disconnect door lock/unlock switch RH connector.
Check continuity between door lock/unlock switch RH terminals.
Door lock/unlock switch RH | Condition | Continuity | ||
---|---|---|---|---|
Terminal | ||||
1 | 4 | Door lock/unlock switch RH | LOCK | No |
UNLOCK | Yes | |||
2 | LOCK | Yes | ||
UNLOCK | No |
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace door lock/unlock switch RH. Refer to Removal and Installation.