CHECK FAIL-SAFE ACTIVATION
Check if the symptom is caused by a fail-safe operation. Refer to Fail-safe.
Is fail-safe operating?
YES>>Repair the part causing fail-safe operation.
NO>>GO TO 2.
CHECK INVERTER UNIT POWER SUPPLY CIRCUIT
Check inverter unit power supply circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace the malfunctioning parts.
CHECK INVERTER UNIT POWER OUTPUT CIRCUIT
Check inverter unit power output circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>Refer to Intermittent Incident.
NO>>Repair or replace the malfunctioning parts.
Because of modified sine wave output, the AC 120 V outlet may not operate normally for electric appliance of which electric power consumption is 150 W or less.
Electric appliances requiring a large amount of electric power consumption at startup (e.g., CRT-based TV, power tool)
Measuring instruments for data requiring accuracy (e.g., medical equipment, measuring instrument)
Microprocessor-controlled appliances (e.g., microprocessor-controlled blanket)
Noise may be caused in radio or TV, depending on an electric appliance.