CHECK FUSES
Check that the following fuses are not blown:
Signal name | Fuse No. | Capacity |
---|---|---|
Battery power supply | 89 | 20 A |
Ignition power supply | 4 | 10 A |
Is the fuse blown?
YES>>Replace the blown fuse after repairing the affected circuit.
NO>>GO TO 2.
CHECK INVERTER UNIT POWER SUPPLY CIRCUIT
Disconnect inverter unit connector.
Check voltage between inverter unit harness connector and ground.
(+) | (-) |
Voltage (Approx.) | |
---|---|---|---|
Inverter unit | |||
Connector | Terminal | ||
B121 | 4 | Ground | Battery voltage |
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace the inverter unit power supply circuit.
CHECK INVERTER UNIT GROUND CIRCUIT
Check continuity between inverter unit harness connector and ground.
Inverter unit | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
B121 | 8 | Ground | Yes |
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace the inverter unit ground circuit.
CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET
Ignition switch OFF.
Disconnect inverter unit and AC 120 V outlet connectors.
Check continuity between inverter unit harness connector and AC 120 V outlet harness connector.
Inverter unit | AC 120 V outlet | Continuity | ||
---|---|---|---|---|
Connector | Terminal | Connector | Terminal | |
B121 | 5 | M88 | 1 | Yes |
1 | 4 |
Check continuity between inverter unit harness connector and ground.
Inverter unit | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
B121 | 5 | Ground | No |
1 |
Check continuity between inverter unit harness connector.
Inverter unit | Continuity | ||
---|---|---|---|
Connector | Terminals | ||
B121 | 5 | 1 | No |
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace the harness or connectors.
CHECK INVERTER UNIT OUTPUT SIGNAL
Connect inverter unit and AC 120 V outlet connector.
Ignition switch ON.
Check voltage between inverter unit harness connector.
CAUTION:
To measure AC 120 V output signal, always use the circuit tester AC range.
Never allow the probes to contact each other.
Inverter unit | Condition |
Voltage (Approx.) | |
---|---|---|---|
Terminals | |||
(+) | (-) | Ignition ON. | |
5 | 1 | OFF | 0 V |
ON | AC 120 V |
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace inverter unit.
CHECK AC 120V OUTLET VOLTAGE
Check voltage between AC 120 V outlet.
CAUTION:
To measure AC 120 V output signal, always use the circuit tester AC range.
Never allow the probes to contact each other.
AC 120 V outlet | Condition |
Voltage (Approx.) | |
---|---|---|---|
Terminals | |||
(+) | (-) | Ignition ON. | |
1 | 4 | OFF | 0 V |
ON | AC 120 V |
Is the inspection result normal?
YES>>GO TO 4.
NO>>Replace AC 120 V outlet.
CHECK AC 120V OUTLET GROUND CIRCUIT
Ignition switch OFF.
Disconnect AC 120 V outlet connector.
Check continuity between AC 120 V outlet harness connector and ground.
AC 120V outlet | — | Continuity | |
---|---|---|---|
Connector | Terminal | ||
M88 | 3 | Ground | Yes |
Is the inspection result normal?
YES>>Replace AC 120 V outlet.
NO>>Repair AC 120 V outlet ground circuit.