CHECK FUSES
Check that the following fuses are not blown:
| Signal name | Fuse No. | Capacity |
|---|---|---|
| Battery power supply | 89 | 20 A |
| Ignition power supply | 4 | 10 A |
Is the fuse blown?
YES>>Replace the blown fuse after repairing the affected circuit.
NO>>GO TO 2.
CHECK INVERTER UNIT POWER SUPPLY CIRCUIT
Disconnect inverter unit connector.
Check voltage between inverter unit harness connector and ground.
| (+) | (-) |
Voltage (Approx.) | |
|---|---|---|---|
| Inverter unit | |||
| Connector | Terminal | ||
| B121 | 4 | Ground | Battery voltage |
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace the inverter unit power supply circuit.
CHECK INVERTER UNIT GROUND CIRCUIT
Check continuity between inverter unit harness connector and ground.
| Inverter unit | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| B121 | 8 | Ground | Yes |
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace the inverter unit ground circuit.
CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET
Ignition switch OFF.
Disconnect inverter unit and AC 120 V outlet connectors.
Check continuity between inverter unit harness connector and AC 120 V outlet harness connector.
| Inverter unit | AC 120 V outlet | Continuity | ||
|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |
| B121 | 5 | M88 | 1 | Yes |
| 1 | 4 | |||
Check continuity between inverter unit harness connector and ground.
| Inverter unit | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| B121 | 5 | Ground | No |
| 1 | |||
Check continuity between inverter unit harness connector.
| Inverter unit | Continuity | ||
|---|---|---|---|
| Connector | Terminals | ||
| B121 | 5 | 1 | No |
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace the harness or connectors.
CHECK INVERTER UNIT OUTPUT SIGNAL
Connect inverter unit and AC 120 V outlet connector.
Ignition switch ON.
Check voltage between inverter unit harness connector.
CAUTION:
To measure AC 120 V output signal, always use the circuit tester AC range.
Never allow the probes to contact each other.
| Inverter unit | Condition |
Voltage (Approx.) | |
|---|---|---|---|
| Terminals | |||
| (+) | (-) | Ignition ON. | |
| 5 | 1 | OFF | 0 V |
| ON | AC 120 V | ||
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace inverter unit.
CHECK AC 120V OUTLET VOLTAGE
Check voltage between AC 120 V outlet.
CAUTION:
To measure AC 120 V output signal, always use the circuit tester AC range.
Never allow the probes to contact each other.
| AC 120 V outlet | Condition |
Voltage (Approx.) | |
|---|---|---|---|
| Terminals | |||
| (+) | (-) | Ignition ON. | |
| 1 | 4 | OFF | 0 V |
| ON | AC 120 V | ||
Is the inspection result normal?
YES>>GO TO 4.
NO>>Replace AC 120 V outlet.
CHECK AC 120V OUTLET GROUND CIRCUIT
Ignition switch OFF.
Disconnect AC 120 V outlet connector.
Check continuity between AC 120 V outlet harness connector and ground.
| AC 120V outlet | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| M88 | 3 | Ground | Yes |
Is the inspection result normal?
YES>>Replace AC 120 V outlet.
NO>>Repair AC 120 V outlet ground circuit.
Nissan Pathfinder Info Center
Email: info@nipathfinder.com
Phone: +1 (800) 123-4567
Address: 123 Pathfinder Blvd, Nashville, TN 37214, USA
Working Hours: Mon–Fri, 9:00 AM – 5:00 PM (EST)